Description
The Vexcolt FireFlex 2300-A07/A09 is a fire-rated expansion joint tested to EN 1366-4 and classified to EN 13501-2, with 2-hour (120-minute), 3-hour (180-minute) and 4-hour (240-minute) fire rated integrity for 25–300 mm gaps. Ceramic fibre infill, stainless steel foil sheath.
| Fire Barrier Selection Criteria | Load Rating | Product Details | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Joint Location |
Gap Width B (mm) |
Movement Capacity (mm) |
Eurocode Rating | Product Dimensions | Product Number |
|||||||
| ± | [Total] | Height | Sightline | Blockout | ||||||||
| H1 (mm) | H2 (mm) | |||||||||||
| 2 Hour (120 mins) Fire Rated Integrity | ||||||||||||
| Wall – Wall Ceiling – Ceiling |
25 | ± 12.5 | [25] | – | – | – | – | 175 | – | – | – | 2300–A07/9–025–002 |
| 35 | ± 17.5 | [35] | 185 | – | – | 2300–A07/9–035–002 | ||||||
| 50 | ± 25 | [50] | 200 | – | – | 2300–A07/9–050–002 | ||||||
| 60 | ± 30 | [60] | 210 | – | – | 2300–A07/9–060–002 | ||||||
| 80 | ± 40 | [80] | 230 | – | – | 2300–A07/9–080–002 | ||||||
| 100 | ± 50 | [100] | 250 | – | – | 2300–A07/9–100–002 | ||||||
| 120 | ± 60 | [120] | 270 | – | – | 2300–A07/9–120–002 | ||||||
| 150 | ± 75 | [150] | 300 | – | – | 2300–A07/9–150–002 | ||||||
| 200 | ± 100 | [200] | 350 | – | – | 2300–A07/9–200–002 | ||||||
| 250 | ± 125 | [250] | 400 | – | – | 2300–A07/9–250–002 | ||||||
| 300 | ± 150 | [300] | 450 | – | – | 2300–A07/9–300–002 | ||||||
| 3 Hour (180 mins) Fire Rated Integrity | ||||||||||||
| Wall – Wall Ceiling – Ceiling |
25 | ± 12.5 | [25] | – | – | – | – | 175 | – | – | – | 2300–A07/9–025–003 |
| 35 | ± 17.5 | [35] | 185 | – | – | 2300–A07/9–035–003 | ||||||
| 50 | ± 25 | [50] | 200 | – | – | 2300–A07/9–050–003 | ||||||
| 60 | ± 30 | [60] | 210 | – | – | 2300–A07/9–060–003 | ||||||
| 80 | ± 40 | [80] | 230 | – | – | 2300–A07/9–080–003 | ||||||
| 100 | ± 50 | [100] | 250 | – | – | 2300–A07/9–100–003 | ||||||
| 120 | ± 60 | [120] | 270 | – | – | 2300–A07/9–120–003 | ||||||
| 150 | ± 75 | [150] | 300 | – | – | 2300–A07/9–150–003 | ||||||
| 200 | ± 100 | [200] | 350 | – | – | 2300–A07/9–200–003 | ||||||
| 250 | ± 125 | [250] | 400 | – | – | 2300–A07/9–250–003 | ||||||
| 300 | ± 150 | [300] | 450 | – | – | 2300–A07/9–300–003 | ||||||
| 4 Hour (240 mins) Fire Rated Integrity | ||||||||||||
| Wall – Wall Ceiling – Ceiling |
25 | ± 12.5 | [25] | – | – | – | – | 175 | – | – | – | 2300–A07/9–025–004 |
| 35 | ± 17.5 | [35] | 185 | – | – | 2300–A07/9–035–004 | ||||||
| 50 | ± 25 | [50] | 200 | – | – | 2300–A07/9–050–004 | ||||||
| 60 | ± 30 | [60] | 210 | – | – | 2300–A07/9–060–004 | ||||||
| 80 | ± 40 | [80] | 230 | – | – | 2300–A07/9–080–004 | ||||||
| 100 | ± 50 | [100] | 250 | – | – | 2300–A07/9–100–004 | ||||||
| 120 | ± 60 | [120] | 270 | – | – | 2300–A07/9–120–004 | ||||||
| 150 | ± 75 | [150] | 300 | – | – | 2300–A07/9–150–004 | ||||||
| 200 | ± 100 | [200] | 350 | – | – | 2300–A07/9–200–004 | ||||||
| 250 | ± 125 | [250] | 400 | – | – | 2300–A07/9–250–004 | ||||||
| 300 | ± 150 | [300] | 450 | – | – | 2300–A07/9–300–004 | ||||||
This product is supplied in various metre lengths depending on the gap width.